•Temperature: 15° to 30°C (59° to 86°F)
Ambient room temperatures above 30°C (86°F) or below 15°C (59°F) will destabilize processingand replenisher solution temperatures to the detriment of processing performance. Pay special
attention to room temperatures in wintertime and maintain solution temperatures within designated
ranges.
•Relative Humidity: 30% to 70%
Relative humidities above 70% will result in inadequate printer paper transport or improper paperdrying, producing abnormal prints. Maintain the ambient room relative humidity within the range of
30% to 70% RH at all times.
•Ventilation
Provide a vent close to the processor section and maintain adequate ventilation.•Illumination: 500 lux or lower
Maintain room illumination levels so that no more than 500 lux falls on the scanner and printerupper surfaces. Should the equipment main body or paper magazine be exposed to direct outside
light or strong reflected light, use curtains or blinds to shield the equipment from such extraneous
light.
REFERENCE:
Two 40W fluorescent lamps provide 500 lux of illumination at a distance of 1 meter (3.3 ft.)
NOTE:Excessively-high indoor illumination levels will adversely affect the quality of finished prints.
No comments:
Post a Comment