Trouble Code List For Electrical Installation of Toyota DX8 and Toyota DX8LT Draw Frame
Trouble Code List
CODE
|
MESSAGE
|
DEAL
|
3000
|
Power Source Trouble
|
Check the circuit protector(CPB2)
|
3010
|
Air Pressure Power fail
|
Check primary pressure {PSW} and pressure piping.
|
3020
|
Inverter Trouble
|
Check the inverter error code to find a possible cause.
|
3030
|
PLC Trouble
|
Replace the sequencer{FX1N}
|
3040
|
Sliver breaks off on creel
|
Check photo switches {PH1-4} on the creel.
|
3041
|
Sliver breaks off on lifter roller
|
Check earth stop{E
|
3043
|
Roller lapping up {R}
|
Check Micro switchs{LS1~4} of the roller part.
|
3044
|
Sliver clogged up in gatherer {R}
|
Check the photo switch {PH6} on the gatherer.
|
3045
|
Counter of over full can
|
Check surplus wind setting time.
|
3046
|
Delay time of tube normal position
|
Check the proximity switch{PS1}
|
3047
|
Can change trouble
|
Check the can changer load.
|
3047
|
Door open
|
Check the limit switchs{DS1~4} of the door.
|
3049
|
No spare can
|
Check Spare can is supplied
|
3053
|
Roller lapping up{L}
|
Check Microswitchs{LS1~4} of the roller part.
|
3054
|
Sliver clogged up in gatherer {L}
|
Check the photo switch {PH6} on the gatherer.
|
3055
|
Positive sliver cutting trouble
|
Check Auto switch
|
3061
|
Main motor overloaded trouble
|
Check thermal{Th2}on Mahnet connector or heat generated on
Main Motor{Th01}
|
3070
|
Can change cylinder irregular irregular position
|
Check Auto switch AS3.6.8.10.12
|
3071
|
Sliver cutting cylinder irregular position
|
Check Auto switch-AS14.16.18
|
hey this is haroon from pakistan, i have to discuss an issue.DX8 LT left side grains are not equal to actual sliver weight.Main CPU card repaired many times on demand but no change.can u tell me the reason.